GENERAL PROVISIONS REGARDING SITE AND BUILDING
REQUIREMENTS
(23)
General requirement regarding plot
(1)
No land development or redevelopment shall be
made or no building shall be constructed on any
plot on any part of which there is deposited refuse,
excreta or other offensive matter which in the
opinion of the Secretary is considered objectionable,
until such refuse, excreta or other offensive
matter has been removed there from and the plot
has been prepared or left in a manner suitable
fro land development or building purpose for he
satisfaction of the Secretary.
2)
No land development or redevelopment shall be
made or no building shall be constructed on a
plot, which comprises or includes a pit, quarry
or other similar excavation or any part thereof
unless such plot has been prepared or left in
a manner or condition suitable for land development
or redevelopment or building purposes to the satisfaction
of the Secretary.
(3)
No land development or redevelopment shall be
made or no building shall be constructed on a
plot liable to flood or on a slop forming an angle
of more than 45 degrees with horizontal or on
soil unsuitable for percolation or more on area
shown as floodable area in any town planning scheme
or in sandy beds, unless it is proved by the owner
to the satisfaction of the Secretary that construction
of such a building will not be dangerous or injurious
to health and the site will not be subjected to
flooding or erosion or cause undue expenditure
of public funds in the provisions of roads, sewers,
sanitation, water supply or other public services.
(4)
Any land development or redevelopment or building
construction or reconstruction in any area notified
by the Government of India as a coastal regulation
zone under the Environment (Protection) Act, 1986
(29 of 1986).
(5)
No building or part of a building shall be constructed
or reconstructed or no additio9n or alteration
shall be made to any existing building in the
intervening spaces between the building and any
overhead electric supply line as described in
the Table I below or specified in the Indian Electricity
Rules.
| # |
Type
of Electric Supply Line |
Vertical
clearance in meters |
Horizontal
clearance in meters |
| (1) |
(2) |
(3) |
(4) |
| 1 |
Low
and medium voltage lines |
2.4 |
1.2 |
| 2 |
High
Voltage Lines upto and including 33,000 Volts |
3.7 |
1.85 |
| 3 |
Extra
High Voltage Lineexcluding 33,000 Volts |
3.7+0.3
m for every additional 33,000 Volts or part
thereof |
1.85+0.3m
for every additional 33,000Volts or part thereof |
(6)
The provisions contained in sub-rule (1) or sub-rule
(2) shall apply invariable to all buildings where
the front, rear and side, yard abuts a street
or gain access through a street. |